12VDC 25Amp 18 Channel Battery Back-up CCTV power store / power station12VDC25A18P/B
Description:
12VDC25A18P/B: 12VDC 25Amp 18 Channel Battery Back-up CCTV Power Supply
The CCTV power supply is primarily designed for WUF-GV, PTZ and camera of CCTV system. It’s also used for access, building/house control, intrude alarm and other light-current. It is for desktop or wall-mounted installation.
Features:
ᅳ Soft starting current, effectively reduce the impact of AC input, independent short-circuit protection and surge protection, resume automatically after clearing of fault, EMI filter, minimum ripple, 100% load test, quality guarantee, high efficiency, low T-rise, continuous duty
ᅳ Input with a switch, LED indicators lighten when the power supply operates normally, and each output contains independent PTC, LED indicator, which is not interfere with each other
ᅳ 12 Volt DC 25Amp switch mode power supply
ᅳ 18 individually PTC auto-reset fuses protected outputs with LED
ᅳ Backup battery: 12V 7AH
ᅳ Charging Current: 350mA
ᅳ Switch mode power supply (regulated voltage)
ᅳ Integral surge protection
ᅳ Individual LED power indication
ᅳ Individual PTC reset-able fuses
ᅳ Internal On/off safety power switch with LED indicator
ᅳ Beige metal housing
Technical specifications:
Model
|
12VDC25A18P/B
|
Power
|
300W
|
Metal Case Dimension
|
37.7×33.2×8.2cm
|
Net Weight
|
4.26kgs
|
Input
|
Input Voltage
|
110/220VAC
|
Input Voltage Frequency
|
50Hz-60Hz
|
Output
|
Output Voltage
|
12VDC±5%
|
Output Current
|
25A,18 channels for 18 sets load
|
Output Ripple Noise(Vp-p)
|
80mVp-p@25℃/
Rated input voltage & Rated output load
|
Reply Time of Starting up
|
≤3S Input 100Vac, Rated output load
|
Fuse
|
Type /Rating
|
PTC 1.85A/60V
|
Protection
|
Over voltage protection
|
When over voltage occurs, it will be switch to self-protection status to protect the load.
|
Over current protection
|
When over current occurs, the corresponding channel output will automatically switch to self-protection status, and the other channels output work normally, when clearing of fault, then switch back to normal.
|
Short-circuit Protection
|
When short-circuit occurs, the individual PTC fuse will break the circuit. When the fault is cleared, it will switch back to normal automatically.
|
Charge
|
The power supply will automatically switch to storage battery if there is outage.
|
Circumstances
|
Working Temperature
|
0℃-+50℃
|
Storage Temperature
|
-20℃-+80℃
|
RH
|
20%-90%
|
Heat Release
|
Natural heat dissipation
|
Connection
|
Input
|
Three-pin socket
|
Output
|
18 channels output
|
Dielectric Strength
|
Input to output
|
1500Vac/60S leakage current≤1.5mA
|
Input to FG
|
1500Vac/60S leakage current≤2.0mA
|
FG to output
|
500Vac/60S leakage current≤1.5mA
|
Insulating strength
|
Input to output
|
≥20MΩ/500VDC@25℃
|
Leakage Current
|
≤0.09mA @AC110V(220V)/25℃
|
RG
|
≤0.005Ω@DC8V/25A/25℃
|